The LevelMetrics™  Series of measurement systems is designed for non-contact distance measurement and object detection applications operating in air or other non-flammable gas environments. They use the "time of flight" method to measure the distance between the sensor and the target. This is done by generating a pulse of acoustic energy that travels out from the sensor face and reflects off the target. When the energy returns to the sensor, the time that it took to travel out and back is measured, and the range to the target is determined based on the known velocity of sound. To operate reliably, the sensor should be placed so that the expected position of the target always falls within the minimum and maximum operating range of the sensor.

The ideal target is hard, smooth, and perpendicular to the sensor axis. Clearly, not all applications will meet all of these conditions, and the LevelMetrics Series goes a long way towards minimizing the effects of non-ideal targets, but the user should keep in mind that as conditions vary from the ideal, sensor range and measurement accuracy may be compromised.


Non-Contact systems optimized for target ranges from 1.25 in. to 240 in.
(Patent# US 2003/0081502 A1)


(Patent# US 2003/0081502 A1)

 

LevelMetrics™ Series 1000/2000/3000
Controller Specifications
 

LM1000

LM2000

LM3000

Purpose Short to long-range, between 4" and  240" Short to long-range, between 4" and 96" Short range, between 1.25" and 10"
Accuracy +/- 0.1 in. (+/-2.54mm) +/- 0.01 in. (+/-0.254mm) +/- 0.001 in. (+/-.0254mm)
Resolution +/- 0.1 in. (+/-2.54mm) +/- 0.01 in. (+/-0.254mm) +/- 0.001 in. (+/-0.0254mm)
Supply Voltage 10 - 14 VDC, (12VDC NOM.) 10 - 14 VDC, (12VDC NOM.) 14 - 10 VDC, (12VDC NOM.)
Power Consumption 5W (Max) 5W (Max) 5W (Max)
Electronics Operating Temperature -40ºF to 122ºF (-40º to 50ºC) -40ºF to 122ºF (-40ºC to 50ºC) -40ºF to 122ºF (-40ºC to 50ºC)
Output Standard:
2 1A SPDT relays configurable for setpoints or alarm
Standard:
2 1A SPDT relays configurable for setpoints or alarm
Standard:
2 1A SPDT relays configurable for setpoints or alarm
Optional:
2 additional relays;
4-20mA or 0-10VDC analog output
Optional:
2 additional relays;
4-20mA or 0-10VDC analog output
Optional:
2 additional relays;
4-20mA or 0-10VDC analog output
Local Display PDA (Personal Digital Assistant, i.e. Palm Pilot or similar) PDA (Personal Digital Assistant, i.e. Palm Pilot or similar) PDA (Personal Digital Assistant, i.e. Palm Pilot or similar)
Computer Interface Serial data interface (RS232),
"DataView" Software available for Windows 95/98/2000/NT/XP
Serial data interface (RS232),
"DataView" Software available for Windows 95/98/2000/NT/XP
Serial data interface (RS232),
"DataView" Software available for Windows 95/98/2000/NT/XP
Enclosure Standard:
Extruded Aluminum with Powder Coat Paint
Standard:
Extruded Aluminum with Powder Coat Paint
Standard:
Extruded Aluminum with Powder Coat Paint
Temperature Sensor Resolution

0.125º C

0.125ºC

0.125ºC

Temperature Sensor Accuracy

+/- 0.5ºC

+/- 0.5ºC

+/- 0.5ºC

 

LevelMetrics™ Series 1000/2000/3000
Sensor Specifications
LMS- 040 Sensing Range 4" to 96" (10.2 cm to 91.4 cm)
  Dimensions 1.0" (25.4 mm) dia. x 3.5" (89 mm) length
  Mounting 1.25" NPT Threads
  Connector

Attached via Mini-DIM connector mounted in sensor

Cable length, up to 40' (10' standard)

LMS-015 Sensing Range 15" to 240" (.38 m to 6.10 m)
  Dimensions 2.0" (50.8 mm) dia. x 5.85" (148.6 mm) length
  Mounting 2" NPT Threads
  Connector

Integral Mini-DIM connector on sensor

Cable length, up to 40’ (10' standard)

MMS-010/011 Sensing Range 1" to 3" (25.4 mm to 76.2 mm)
  Dimensions 0.25" (6.35 mm) dia. x 1.875" (47.6 mm) length
  Mounting Clamp mount
  Connector

Integral AMP miniature coaxial connector (MMS-010) or cable extension with connector (MMS-011)

Cable length up to 10’ (10' standard)

MMS-015 Sensing Range 1.25" to 4" (31.8 mm to 76.2 mm)
  Dimensions 0.39" (10.0 mm) dia. x 1.875" (47.6 mm) length
  Mounting Clamp mount
  Connector

Integral AMP miniature coaxial connector  or cable extension with connector (MMS-016)

Cable length up to 40' (10' standard)

MMS-020/21 Sensing Range 1.25" to 5" (31.8 mm to 127 mm)
  Dimensions 0.625" (15.9 mm) dia. x 2.10" (53.3 mm) length
  Mounting 0.625" / 11 Straight threads
  Connector

Integral Mini-DIM connector (MMS-020), or cable extension with connector (MMS-021)

Cable length up to 40' (10' standard)

MMS-030 Sensing Range 1.5" to 12" (38.1 mm to 304.8 mm)
  Dimensions 1.0" (25.4 mm) dia. x 2.75" (69.9 mm) length
  Mounting 1.0" / 12 Straight threads
  Connector Integral Mini-DIM connector. Cable length up to 40' (10' standard)

 

LevelMetrics™ Series 1000/2000/3000
Sensor Diagrams

 

LevelMetrics LMS-040 Sensor

 

 

 

 

 

 

LevelMetrics LMS-015 Sensor

 

 

 

 

 

 

LevelMetrics MMS-010 Sensor

 

LevelMetrics MMS-011 Sensor

 

 

LevelMetrics MMS-020 Sensor

 

 

LevelMetrics MMS-021 Sensor

 

 

LevelMetrics MMS-030 Sensor